产物分类
Product Category详细介绍
品牌 | 础滨搁罢滨惭贰厂/中航时代 |
---|
橡胶塑料介电击穿强度试验仪/耐电压强度试验机
Dielectric breakdown strength tester
产物名称:介电击穿强度测定仪
Product name: dielectric breakdown strength tester
产物型号:叠顿闯颁-100碍痴
Product model: BDJC - 100 kv
控制方式:微机控制橡胶塑料介电击穿强度试验仪/耐电压强度试验机
Control mode: microcomputer control
满足标准:GB1408-2006 绝缘材料电气强度试验方法
Meet the standard: GB1408 2006 insulation dielectric strength test method
GB/T1695-2005 硫化橡胶工频电压击穿强度和耐电压强度试验
GB/T1695-2005 rubber power frequency voltage breakdown strength and voltage resistance strength test
GB/T3333 电缆纸工频电压击穿试验方法
GB/T3333 cable ZhiGong frequency voltage breakdown test method
HG/T 3330绝缘漆漆膜击穿强度测定法
HG/T 3330 insulating varnish film breakdown strength measurement
GB12656 电容器纸工频电压击穿试验方法
GB12656 ZhiGong frequency capacitor voltage breakdown test method
ASTM D149 固体电绝缘材料在工业电源频率下的介电击穿电压和介电强度的试验方法.
ASTM D149 solid electrical insulating materials in the industrial power frequency of dielectric breakdown voltage and dielectric strength test method.
一、适用范围及功能
A, scope and function
主要适用于固体绝缘材料(如:塑料、橡胶、薄膜、树脂、云母、陶瓷、玻璃、绝缘漆等介质)在工频电压或直流电压下击穿强度和耐电压的测试。
Mainly applied to solid insulating material (such as plastic, rubber, thin film, resin, mica, ceramic, glass, insulating paint, etc.) under power frequency voltage or dc voltage breakdown strength and withstand voltage test.
本仪器由电脑控制,通过我公司自主研发的全新智能数字集成电路系统与软件控制系统两部分来完成,使升压速率真正做到匀速、准确,并能够准确测出漏电电流的数据。可实时绘制试验曲线,显示试验数据,判断准确,并可保存,分析,打印试验数据。
The instrument is controlled by computer, through my company independent research and development of new inligent digital integrated circuit system and the software two parts to complete the control system, make the pressure rise rate really uniform and accurate, and can accuray measure the data of leakage current. Can be real-time rendering test curve, according to the test data, accurate, and can save, analysis, print the test data.
自主知识产权(国内*,)
Independent inlectual property rights (the first domestic, international lead)
二、技术要求:
Second, the technical requirements:
01、输入电压: 交流 220 V
01, input voltage, ac 220 V
02、输出电压: 交流 0--100 KV ;
02, output voltage: communication 0-100 KV;
直流 0—100 KV
Dc 0-100 KV
03、电器容量: 5KVA
03, electric capacity: 5 kva
04、高压分级: 0-10KV,0--50KV,0-100KV
04, high-pressure sizing: 0 to 10 kv, 0, 50 kv, 0-100 kv
05、升压速率: 100V/S 200V/S 500 V/S 1000 V/S 2000V/S 3000V/S 等
05, pressure rise rate: 100 V/S/S/S 1000 V, 500 V, 200 V / 2000 V / 3000 V/S S S, etc
(备注:满足标准要求并可以根据用户需求设定不同的升压速率)
(note: meet the standard requirements and can be set according to user requirements different pressure rise rate)
06、试验方式:
06, test mode:
直流试验:1、匀速升压 2、梯度升压 3、耐压试验
Dc test: 1, 2, gradient booster 3 uniform booster, withstand voltage test
交流试验:1、匀速升压 2、梯度升压 3、耐压试验
Ac test: 1, 2, gradient booster 3 uniform booster, withstand voltage test
07、试验介质:空气,试验油
07, test medium: air, test oil
08、安装灵敏度较高的过电流保护装置保证试样击穿时在0.05厂内切断电源。
08, installation high sensitivity of overcurrent protection device to ensure the sample breakdown when cut off the power supply within 0.05 S.
09、采用智能集成电路进行匀速升压。
09, inligent integrated circuit is adopted to improve the pressure at a constant speed.
10、支持短时间内短路试验要求。
10 short circuit test requirements, support for a short time.
11、电压试验精度: ≤ 1%。
11, voltage test accuracy: 1% or less.
12、试验电压连续可调: 0--100 KV。
12, test voltage adjustable: 0-100 KV.
13、电流可采集到尘*。
13, current can be collected to mA.
14、出具*计量单位航天二院203所的校准检定证书或出具客户计量单位的证书。
14, issued by national level units of measure space 2 hospital 203 calibration verification certificate, or issue the certificate of customers specify the units of measurement.
叁、安全保护
3, safety protection
本试验仪器电路保护控制:
This test instrument circuit protection control:
(1)超压保护 (2)过流保护 (3)短路保护(4)漏电保护 (5)软件误操作保护
(1) the overpressure protection over-current protection (2) (3) short circuit protection (4) leakage protection misoperation (5) software protection
高压输入回路断电保护控制:
High voltage power input circuit protection control:
(1)总电源开关 (2)调压器复位开关 (3)高压断电开关
(1) the total power switch (2) voltage regulator reset switch (3) the high voltage power switch
(4)试验箱门安全开关 (5)高压回路开关 (6)漏电保护开关
(4) test the door safety switch (5) high pressure circuit switch (6) leakage protection switch
四、设备主要配置
Four main configuration, equipment
设备标准配置
Equipment standard configuration
序号 名称 配置 备注
Serial number name of the configuration notes
01 试验主机 一台
01 a test hosts
02 控制装置 一套
02 a control device
03 试验电极 二套(国标1408.1)
03 2 sets test electrode (1408.1 gb)
04 试验油箱 二只
04 test two tank
05 放电系统 一套
A set of 5 discharge system
06 控制系统 一套
6 a set of control system
07 数据采集系统 一套
7 a set of data acquisition system
08 试验软件 一套 光盘
Test software is a set of CD
09 计算机 一套 品牌
09 computer a brand
10 喷墨打印机 一台 品牌
10 a brand inkjet printer
11 产物使用说明书 一份
A 11 product instruction for use
12 计量证书 一份
12 a measurement certificate
13 产物合格证 一份
A 13 product certificate
五、此设备常规型号为:
Five, the conventional model is as follows:
BDJC-10KV
BDJC - 10 kv
BDJC-20KV
BDJC - 20 kv
BDJC-30KV
BDJC - 30 kv
BDJC-50KV
BDJC - 50 kv
BDJC-100KV
BDJC - 100 k
产物咨询
电话
微信扫一扫